bluesky.plans.rel_adaptive_scan¶
-
bluesky.plans.
rel_adaptive_scan
(detectors, target_field, motor, start, stop, min_step, max_step, target_delta, backstep, threshold=0.8, *, md=None)[source]¶ Relative scan over one variable with adaptively tuned step size.
- Parameters
- detectorslist
list of ‘readable’ objects
- target_fieldstring
data field whose output is the focus of the adaptive tuning
- motorobject
any ‘settable’ object (motor, temp controller, etc.)
- startfloat
starting position of motor
- stopfloat
ending position of motor
- min_stepfloat
smallest step for fast-changing regions
- max_stepfloat
largest step for slow-chaning regions
- target_deltafloat
desired fractional change in detector signal between steps
- backstepbool
whether backward steps are allowed – this is concern with some motors
- thresholdfloat, optional
threshold for going backward and rescanning a region, default is 0.8
- mddict, optional
metadata
See also